Hardware
| Model & Expansions | Hostname / Label & Console Cable | Telnet Port & Baud | |||
|---|---|---|---|---|---|
| Cisco 2600 Router | NM-4E Ethernet module, WIC 2T | R1 | 1 | 6033 | 115200 |
| Cisco 2600 Router | NM-4E Ethernet module, WIC 2T, WIC 1T | R2 | 2 | 6034 | 115200 |
| Cisco 2600 Router | NM-4E Ethernet module, WIC 2T, WIC 1T | R3 | 3 | 6035 | 115200 |
| Cisco 2600 Serial Console | NM-32A Async Serial module | SC1 | N/A | N/A (Host) | 9600 (NC) |
| Cisco Catalyst 3750 Switch | None | SW1 | 4 | 6036 | 9600 |
| Cisco Catalyst 3750 Switch | None | SW2 | 5 | 6037 | 9600 |
| Cisco Catalyst 3750 Switch | None | SW3 | 6 | 6038 | 9600 |
| Cisco Catalyst 3750 Switch | None | SW4 | 7 | 6039 | 9600 |
| Netgear FS108 Switch | Attached to SC1, which runs DHCP | (Actually 's | N/A | N/A | N/A |
This stuff is all in the network training rack (The 12U flight case)
Basics
The serial console server (SC1) runs DHCP from it's Ethernet 0/0 port (Round the back of the rack). This is usually plugged straight into the Netgear FS108 so via that you can access SC1 over telnet like so:
$ telnet 192.168.0.1
and to access all the other devices over serial via SC1, bearing in mind that the
CABLE_NUM
is the console cable of the target device from the above table.
$ telnet 192.168.0.1 6032+CABLE_NUM
SC1 Serial Config
Enable the elevated privileges mode. Enter the password when prompted. (The # following the hostname indicates that privileged mode is enabled)
sc>enable Password: sc#
You can check the current serial config with
sc#show line
Tty Typ Tx/Rx A Modem Roty AccO AccI Uses Noise Overruns Int
* 0 CTY - - - - - 0 1 0/0 -
33 TTY 115200/115200- - - - - 0 0 0/0 -
34 TTY 115200/115200- - - - - 0 0 0/0 -
35 TTY 115200/115200- - - - - 0 0 0/0 -
36 TTY 9600/9600 - - - - - 0 0 0/0 -
37 TTY 9600/9600 - - - - - 0 0 0/0 -
38 TTY 9600/9600 - - - - - 0 0 0/0 -
...
Enter configuration mode. Hit enter when prompted by the
Configure from terminal, memory, or network [terminal]?
line.
sc#configure Configuring from terminal, memory, or network [terminal]? Enter configuration commands, one per line. End with CNTL/Z. sc(config)#
Type the following to configure a line. The Async card runs TTYs on lines 33 - 64, with like 33 being the 1st console cable from the hardware table. Use
?
to check the other config details. (33 to 35 is an example - this will config lines 33, 34 & 35)
sc(config)#line tty 33 35 sc(config-line)#
Some of the more useful commands are
rxspeed
&
txspeed
to set the baud rates of the cables you selected.